Air conditioning servicing in Ilford

Has the air conditioning in your Ilford home or business gone a year or more without a visit? We service split and multi-split systems at homes and business premises alike, whoever fitted them. A service cleans what clogs, tests what wears, records how the system performs and tells you whether the law requires a leak check on your unit.

Arrange a service visit

Leave three details and we phone you to talk it through.

Enquiries are shared only with the team who quotes for and does the work. We use your details for this request alone and send no marketing. How we handle your details.

  • Any make, any installer
  • Leak checks where the law needs them
  • Written readings left behind

What does an air conditioning service include?

Cleaning, testing and a written record, outside and in.

Part of the systemWhat we do
Outdoor unitClear leaves, fluff and grime from the coil, check the fan turns freely and the unit sits level and secure
PipeworkInspect joints and insulation for oil marks or damage, the usual signs of a leak
Indoor unitWash the filters, clean the coil and fan wheel
CondensateFlush the tray and drain and run water through, as a clogged drain causes most drips
Electrics and controlsCheck terminals, the isolator and the remote or wall controller
PerformanceMeasure the air going in and coming out, and note the readings for you

Keeping those readings means next year's visit can show whether anything has drifted.

Is a leak check a legal requirement for my unit?

For most new single-room R32 splits, no. GOV.UK requires leak checks once a system's refrigerant reaches 5 tonnes of CO2 equivalent, worked out as the weight of gas in tonnes times its global warming potential (GWP).

Charge in tonnes of CO2 equivalentLeak check at least
Under 5Not required by law
5 to under 50Every 12 months
50 to under 500Every 6 months

GOV.UK's example for the 5-tonne line is 2.4kg of R410A, whose GWP is 2,088. A typical new 2.5kW split runs on R32 instead, GWP 675: Mitsubishi Electric's MSZ-LN25VG2 holds 0.80kg, which its data sheet gives as 0.540 tonnes, about a tenth of the line. Reaching 5 tonnes would take roughly 7.4kg of R32 (our sum). R410A systems holding 2.4kg or more, which usually means larger or multi-room systems, are over it, and an automatic leak detection system doubles the interval. The outdoor unit's rating plate shows the refrigerant and charge, and GOV.UK puts the duty on whoever uses the equipment. Sources: GOV.UK, leak checks; GOV.UK, CO2 equivalent; GOV.UK, global warming potentials; Mitsubishi Electric.

How often should a system be serviced?

Once a year suits most homes, ideally in spring so the system is ready before the first hot spell. Busy shops, salons and kitchens clog filters quicker, and a six-monthly visit often suits them. If the warranty terms set an interval, follow them, since some warranties depend on it. Between visits, rinse the filters yourself every few weeks of heavy use.

What does a service cost nationally?

Checkatrade's May 2026 guide gives £70 to £120 per unit for a one-off service. That is a national figure, not our price. The number of units, how easily we can reach them, whether the system is commercial and whether a legal leak check is due all move it, so tell us what you have and where it sits and we quote before booking. See Ilford air conditioning, from survey to service for how we work across the area. Source: Checkatrade.

Who is allowed to work on the refrigerant side?

Only a technician with the right F-gas qualification. With Category 1 they may do anything; Category 2 is limited to systems under 3kg; Category 4 is for leak checks that leave the circuit closed. A firm doing this on other people's equipment must also hold company certification from Refcom, F-Gas Register (Quidos) or Bureau Veritas, which runs for three years at a time. Cleaning filters needs neither. Ask any firm for both before they open your system, and see the F-gas check guide for how to confirm them. Sources: GOV.UK, F-gas qualifications; GOV.UK, company certification.

Common questions

My unit seems low on gas. Is a refill part of the service?

No. Refrigerant circulates in a sealed circuit and is not used up, so if some is missing it has escaped. Finding and fixing that leak is a repair, done before any refill.

We have no paperwork for our system. Is that a problem?

No. The rating plate gives the make, model, refrigerant and charge, and we start a record from this visit.

Can I clean the filters myself?

Yes, and you should between visits. With the unit switched off, lift the front panel, slide the filters out, rinse them in lukewarm water and let them dry before refitting. Leave the coil, the drain and anything electrical for the service.

Sources for this page

Five things to have handy

Answers to these let us judge, before anyone visits, how involved the job will be.

  • Your postcode
  • The building: terrace, semi, detached, a flat in a block or over a shop, or business premises
  • Whether you own it outright, hold a lease or rent it
  • Which room it is, its rough size, and whether it gets the morning or the afternoon sun
  • Anything that limits outside changes: a conservation area, a listing, a lease clause or a managing agent
Call 020 8176 6154Ask for a quote

Guides to read before you decide

Similar jobs we take on

Everything else we do

Rather we called you?

Your name, phone number and postcode are all we need to call you. A word about the room helps us come prepared. You can also call 020 8176 6154.

Enquiries are shared only with the team who quotes for and does the work. We use your details for this request alone and send no marketing. How we handle your details.

Call us020 8176 6154Ask for a quoteWe ring you back